11/20/2023 0 Comments Tec superflexDo not add any foreign substances during mixing and application.In the case of waterproofing water-impermeable concrete structures in the areas of working joints and butt joints of pre-cast concrete elements, comply with the national guideline (if existing) relating to water-impermeable concrete structures.2018, issued by the German Construction Chemicals Association) and the WTA leaflet “Retrospective Waterproofing of Ground-Contacting Structures”. Follow the national standards and/or guidelines; if not issued, and if requested, refer to the norm DIN 18533 “Waterproofing of Ground-contacting Building Structures”, the “Guideline for Planning and Execution of Waterproofing Works with Polymer-Modified Bitumen Coatings (PMBC)” ( 4th edition, Dec.Prior to backfilling the excavation pit use the fleece-lined drainage and protection foil weber.sys 983 over the basement walls in order to protect the waterproofing system.Do not bond protective boards or insulation boards and do not fill the excavation pit until the material has completely dried.In case of sunshine, carry out waterproofing works in shadow or in the morning or evening hours.In case of pressure water steel-reinforced concrete must satisfy the national standards (EN 206) and, if requested DIN 1045.All characteristics mentioned in this data sheet are given for a temperature of +20 ☌, without draft and a relative rate of humidity of 50%.sprayable with peristaltic pump and screw pump technology, e.g.resistant to thawing salts and freeze after full drying.resistant to ageing, to water attacking concrete up to the level "highly corrosive" in accordance with DIN 4030 (up to 3.000 mg sulphate per liter of water) and also to seawater.suitable for any mineral substrates no cement render is necessary on masonry.quickly resistant to rain after 2.5-3 hours at 4 mm layer thickness.a 1.1 mm thick wet layer provides approx.solvent-free, hence environment-friendly.In addition, for spot-bonding or full-surface bonding of extruded polystyrene rigid-foam boards used as protective, drainage or perimeter insulation boards (depending on the specific use) on the pre-said building parts. beneath floor concrete slab), foundations, ceiling slabs of car parking decks in cases of ground damp, non-pressure and pressure water.Īlso, convenient for the intermediate waterproofing of wet-duty rooms, not-inhabited balconies and terraces under floor screed. The application is possible with a masonry brush, brush, trowel, as well as a spraying Superflex 10 is used for the external waterproofing of masonry and concrete below ground level for basement walls, concrete floor slabs, lean concrete (i.e.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |